    Дополнительная информация


    Test System Features

    Transient 3000 CE Test System has many unique and outstanding features:
    - Modular design, user configurable
    - Environmentally friendly
    - Humidity, pressure and temperature sensor measure lab environment
    - Automatic frequency detection for mains synchronisation (50 to 400Hz)
    - Internal web server
    - Ethernet Port for control, communication and report generation
    - USB Port: Secure transfer of files, test reports and service data
    - Common Mode Disturbances DC to 150kHz 30V continuous, 300V short duration
    - ESD 16kV air / 10kV contact discharge
    - ESD 16kV continuous firing mode.
    - Choice of EFT/Burst modules 4kV or 5kV
    - CWG surge up to 4kV/2kA
    - AC Magnetic Field up to 1000A/m (with external antenna)
    - Impulse Magnetic Field 1200A/m
    - AC Interrupt 260V/16A
    - AC DIP and VARIATION with internal, external variac or PS3 power supply
    - DC Interrupt 110V/16A
    - RS485 Port for control of external accessories
    - Control of up to two external PS3 power supplies

    User Benefits

    The technical excellence and many unique features translate directly into benefits for the user:
    - Optimized investment. Feature expansion by on-site upgrades
    - No down time: Modules can be removed for calibration
    - Unparalleled reliability and system up-time
    - Display information in any operating system with any web browser
    - Customized test report, logo import, graphics, time and date
    - Test report includes laboratory environmental conditions
    - No proprietary software needed: HTML Report viewable with all browsers
    - Active energy control system: Low power consumption, less noise, less heat
    - Backwards compatibility: Existing accessories can be used with all models
    - 400Hz CDN use for military and avionics testing
    - Optimized for CE transient testing: Fulfills IEC basic standard requirements
    - Clear menu overview: Structure automatically adjusts to hardware configuration
    - Expansion to 3-phase test system up to 100A
    - Operating history stored in generator for service
    - Modern communication interfaces connect TRA3000 to the world
    - Save operator time with the automated test routines and test report facility

    TRA3000 BASE
    Supply voltage range 80 to 260V / 50Hz & 60Hz
    Standby current 50VA
    Internal CDN voltage rating 280Vac & 110Vdc
    Internal CDN current rating 16Aac & 16Adc
    Internal CDN frequency range 50 to 400Hz
    Power frequency synchronisation 16Hz up to 400Hz
    Coupling path selection EFT L, N, PE, L+N, L+PE, N+PE, L+N+ PE
    Coupling path selection surge L - N, L - PE, N - PE
    Communication Interface Ethernet
    Accessory control interface RS485
    Memory locations unlimited
    Atmospheric measurement Temperature & Humidity
    PS3 control DC, 16.7Hz, 50Hz, 60Hz, 400Hz
    EUT Power monitor 10V =400Vac
    Surge voltage monitor 10V =4kV
    Surge current monitor 10V =2kA
    Trigger BNC maximum 12V
    Trigger mode Auto, manual
    Synchro source Power, external
    Power synchro on/off 0 - 360°
    Power switching before / after test 0 up to 60min.
    EXT-TRA3000 S SURGE Combination Wave Generator (CWG)
    Voltage Range 0.25 up to 4.1kV
    Pulse front time at open circuit 1.2μs
    Pulse duration at open circuit 50μs
    Source Impedance 2ohm
    Current range 0.125 up to 2.05kA
    Pulse front time at short circuit 8μs
    Pulse duration at short circuit 20μs
    Pulse repetition up to 20 pulses per minute
    Programmable parameter ramps voltage, polarity, synchronisation
    S
    T
    A
    N
    D
    A
    R
    D
    S
    T
    R
    A
    3
    0
    0
    0
     
    B
    A
    S
    E
    E
    F
    T
    /
    B
    u
    r
    s
    t
    S
    U
    R
    G
    E
    D
    I
    P
    S
     
    (
    I
    N
    T
    E
    R
    R
    U

    P
    T
    )
    V
    A
    R
    I
    A
    C
    C
    O
    M
    M
    O
    N
     
    M

    O
    D
    E
     
    (
    I
    N
    T
    )
    V
    A
    R
    -
    E
    X
    T

    1
    0
    0
    0
    M
    F
    1
    0
    0
    0

    -
    1
     
    C
    N
    1
    6
     

    (
    T
    )

    C
    N
    -
    E
    F
    T

    1
    0
    0
    0

    P
    S
    3
    E
    X
    T
    -
    T
    R

    A
    3
    0
    0
     E
    C
    O
    M
    M
    O
    N
     
    M
    O
    D
    E
     
    (
    E
    X
    T
    )
    IEC61000-4-2
    IEC61000-4-4
    IEC61000-4-5
    IEC61000-4-8 1
    IEC61000-4-9
    IEC61000-4-11 2 2 3
    IEC61000-4-16
    IEC61000-4-29 4
    ● = necessary  □ = options
    1. PS3 can be used for magnetic field testing including 16.7Hz
    2. Internal and external variac >500A inrush current
    3. PS3 ca. 100A inrush current
    4. Requires 2 x PS3

    Устройства связи/развязки для формирования импульсных помех
    CDN2000-06-32 for Three Phase Coupling

    Add three phase capability with automatic or manual three phase coupling networks.
    The CDN2000A-06-32 and CDN2000-06-32, can be used for EFT, CWG surge and ring
    wave. Coupling path selection is either automatic under software control, or manual
    on the CDN front panel. All coupling networks fulfill the requirements laid down in
    the IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-12 (ring wave) and ANSI C62.41
    standards.
    280V Lx to N/PE, 480V Lx-Lx, 480V Lx/N-PE
    OPTION 480V / CMC enables coupling according to ANSI C62.41 L1+L2+L3+N to PE.

    CDN2000A-06-63 for Three Phase Coupling

    Add higher current three phase capability with automatic coupling network CDN2000A-
    06-63. This can be used for EFT, CWG surge and ring wave. Coupling path
    selection is automatic under software control. This coupling network fulfills the requirements
    laid down in the IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-12 (ring wave)
    and ANSI C62.41 standards.
    280V Lx to N/PE, 480V Lx-Lx, 480V Lx/N-PE

    CDN-A-3P100-480 F / F-S for 100A three Phase Coupling

    Three phase CDN with line voltages L to N/PE=280V and L to L=480V, line current 100A
    per phase. Automatic coupling path selection for EFT or EFT and SURGE controlled
    by TRA2000, TRA2004, TRA2006, TRA3000.

    CDN-A-3P100-690 F / F-S for 100A three Phase Coupling

    Three phase CDN with line voltages L to N/PE=398V and L to L=690V, line current 100A
    per phase. Automatic coupling path selection for EFT or EFT and SURGE controlled
    by TRA2000, TRA2004, TRA2006, TRA3000 and MIG0603INx.

    CDN-A-3P200-480 F / F-S for 200A three Phase Coupling

    Three phase CDN with line voltages L to N/PE=280V and L to L=480V, line current 200A
    per phase. Automatic coupling path selection for EFT or EFT and SURGE controlled
    by TRA2000, TRA2004, TRA2006, TRA3000 and MIG0603INx.

    CDN-A-3P200-690 F / F-S for 200A three Phase Coupling

    Three phase CDN with line voltages L to N/PE=398V and L to L=690V, line current 200A
    per phase. Automatic coupling path selection for EFT or EFT and SURGE controlled
    by TRA2000, TRA2004, TRA2006, TRA3000 and MIG0603INx.

    CDN-A-06-32-AC-DC Surge and EFT CDN

    Combined automatic CDN for Solar Inverter testing on 2 strings. DC+ and DC- up to
    1000V / 32A and AC 3-Phase 690V / 32A. Surge combination wave and EFT in one
    unit.

    Номер в
    госреестре
    Наименование СИ Обозначение типа СИ Изготовитель Срок свидетельства
    или заводской номер
    Не подлежит сертификации

    Запросить цену можно по телефону или заполнив эту несложную форму.

    ФИО:

    Компания:

    Контактные данные: