    E extension PN: 104023
    Electrostatic Discharges (ESD)

    Connected to the IMU4000 front panel on the RS485 data bus, EXT-TRA3000
    E gives 16kV Air discharge and 10kV Contact discharge. The additional “Firing”
    mode enables fault finding using continuous discharges.
    F extension 4kV PN: 106896 / 5kV PN: 106898
    Electric Fast Transient / Burst (EFT)

    Plug-in for the IMU4000 mainframe. EXT-IMU4000 F / F5 generates fully
    compliant impulses up to 4kV / 5kV, meeting and exceeding IEC and EN basic
    standard requirements. HV output for use with Capacitive coupling clamp and
    3-Phase CDNs
    S extension PN: 106897
    Combination Wave Generator /Surge (CWG)

    Plug-in for the IMU4000 mainframe. EXT-IMU4000 S generates fully compliant
    impulses up to 4.1kV, meeting and exceeding IEC and EN basic standard requirements.
    HV output for use with 3-Phase CDNs
    C extension PN: 104028
    Common Mode Generator (CM)

    Plug-in for the IMU4000 mainframe. EXT-TRA3000 C is a complete on-board
    synthesiser for Continuous testing to 35V from DC to 150kHz.
    Combine with the EXT-TRA3000 C-SHORT to perform 300V testing.
    D extension PN: 104031
    AC & DC Interrupts

    Plug-in for the IMU4000 mainframe. EXT-TRA3000 D is an electronic switch for
    interrupt testing to 16A. Can be used with internal (EXT-IMU3000 V) or external
    VAR-EXT1000 for DIP testing.
    V extension PN: 104025
    AC Dips & Variations

    Plug-in for the IMU4000 mainframe.
    EXT-IMU3000 V gives 5A DIP and variation capability.
    IMU SLAVE SMART PN: 105685
    Differential Mode Generator (DM)

    Extension frame for the IMU4000 mainframe. IMU SLAVE SMART can be configured
    for either disturbance voltage tests up to 20V and current tests up to 4A.
    Combine with EXT-SMART PSC10 for current up to 20A or PS3 for voltage up to
    300V.

    Easy Programming
    7” Colour touch panel
    Rotary knob for navigation and data entry EPOS (EMC PARTNER Operating System) a new concept in graphical user interface


    Single Port Testing
    Built in 16A single phase CDN for AC and DC powered EUTs
    Automatic switching between test events
    Complete test report

    User Configurable
    One or many disturbance sources
    Fully modular design
    Grow the system as needs evolve

    Service Friendly
    User replaceable extensions
    Built in self test routines
    USB port to access service data

    Highest Test Levels
    CWG Surge
    Impulse up to 4.1kV
    EFT up to 5kV test level
    Compatible with existing Transient accessories.

    Benefits

    Get Testing Faster
    Your aim is to perform testing
    Minimum learning time
    Easy to follow user interface

    Save Time
    Test setup fast and error free.
    Finish the job quickly
    Get test report information as HTML file

    Upgrade on Site
    Start with a single function tester.
    Add new extensions on site
    Customize to your requirements


    Keep Testing
    Maximize system up time
    Calibrated extensions exchanged on site
    No disruption to the testing program

    Only Need One Tester
    Expandable to include many disturbance tests
    Covers all EMC testing needs
    Cost effective solution

    Standards


    International Electrotechnical Committee (IEC)
    IEC 61000-4-2 : Testing and measurement techniques - Electrostatic discharge immunity test.
    IEC 61000-4-4 : Testing and measurement techniques - Electrical fast transient / burst immunity test.
    IEC 61000-4-5: Testing and measurement techniques - Surge immunity test.
    IEC 61000-4-8: Testing and measurement techniques - Power frequency magnetic field immunity test.
    IEC 61000-4-9: Testing and measurement techniques - Pulse magnetic field immunity test.
    IEC 61000-4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests.
    IEC 61000-4-16 : Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0Hz to 150kHz.
    IEC 61000-4-19 : Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2Hz to 150kHz at ac power ports.
    IEC 61000-4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests.
    IEC 61000-4-34: Testing and measurement techniques - Voltage, dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16A per phase.

    Mainframe Specifications
    IMU4000 Control features
    User Interface 7” Colour touch panel
    Operating System EMC PARTNER (EPOS)
    Communication Interface Ethernet
    Accessory control interface RS485
    Atmospheric measurement Temperature, humidity, pressure (with accessory)
    BNC monitor ports EUT plus IMPULSE voltage & current
    Trigger mode Auto, manual, external
    Synchro source EUT power, Impulse out, External
    Synchro on / off 0° up to 360°
    IMU4000 Coupling Decoupling Network
    Maximum AC voltage 280V
    Maximum DC voltage 300V
    Maximum EUT current 16A
    Frequency range DC up to 60Hz
    Power frequency synchro 16.7 up to 60Hz
    Coupling EFT L, N, PE, L+N, L+PE, N+PE, L+N+PE, direct
    Coupling CWG L-N, L-PE, N-PE, direct
    Electric Fast Transient (Burst)
    EXT-IMU4000 F (EFT 4kV)
    Voltage range 0.25 up to 4.4kV
    Voltage amplitude into 50ohm 0.125 up to 2.0kV
    Voltage amplitude into 1kohm 0.24 up to 4.0kV
    EXT-IMU4000 F5 (EFT 5kV)
    Voltage range 0.25 up to 5.1kV
    Voltgae amplitude into 50ohm 0.125 up to 2.55kV
    Voltage amplitude into 1kohm 0.24 up to 4.8kV
    COMMON EFT SPECIFICATIONS
    Source impedance 50ohm
    Pulse front time at 50ohm 5ns
    Pulse duration at 50ohm 50ns
    Burst duration 0.01 up to 30ms
    Burst repetition 1 up to 1000ms
    Spike repetition frequency up to 1MHz
    Polarity Positive / Negative
    Programmable parameter ramps voltage, spike frequency, burst duration
    Spike distribution IEC burst pattern and random
    IMU4000 Selection Guide
    STANDARDS I
    M
    U
    4
    0
    0
    0
     
    M
    a
    i
    n
    f
    r
    a
    m
    e
    E
    X
    T
    -
    I
    M
    U
    4
    0
    0
    0
     
    F
     
    o
    r
     
    F
    5

    E
    X
    T
    -
    I
    M
    U
    4
    0
    0
    0
     
    S
    E
    X
    T
    -
    T
    R
    A
    3
    0
    0
    0
     
    D
    E
    X
    T
    -
    T
    R
    A
    3
    0
    0
    0
     
    V
    E
    X
    T
    -
    T
    R
    A
    3
    0
    0
    0
     
    C
    E
    x
    t
    e
    r
    n
    a
    l
     
    O
    p
    t
    i
    o
    n
    s
    V
    A
    R
    -
    E
    X
    T
    1
    0
    0
    0

    M
    F
    1
    0
    0
    0
    -
    1
    ,
     
    -
    2

    &
    -
    3
    C
    N
    1
    6
    ,
     
    C
    N
    1
    6
    -
    2
    2
    -
    7

    C
    N
    -
    E
    F
    T
    1
    0
    0
    0

    P
    S
    3

    P
    F
    S
    x
     
    &
     
    S
    R
    C
    x

    E
    X
    T
    -
    T
    R
    A
    3
    0
    0

     E
    E
    X
    T
    -
    T
    R
    A
    3
    0
    0
    0

    C
     
    S
    H
    O
    R
    T
    I
    M
    U
     
    S
    L
    A
    V
    E
     
    S
    M
    A
    R
    T6
    IEC61000-4-2 ESD
    IEC61000-4-4 EFT
    IEC61000-4-5 CWG 2
    IEC61000-4-8 AC MF 1 1
    IEC61000-4-9 Impulse MF
    IEC61000-4-11 AC Dips 2 2
    IEC61000-4-16 Common mode 3 5
    IEC61000-4-19 Differential mode
    IEC61000-4-29 DC Dips 4
    IEC61000-4-34 AC DIPS > 16A
    ● = necessary □ = options
    1. PS3 can be used for magnetic field testing including 16.7Hz
    2. Internal and external variac >500A inrush current
    3. PS3 ca. 100A inrush current frequency range DC to 400Hz
    4. Requires 2 x PS3 for automatic control or customer supplied PSUs for manual control
    5. PS3 required for 300V short duration power frequency tests.
    6. IMU SLAVE SMART requires current or voltage modules.

    IEFT / Burst
    CN-EFT1000 Capacitive coupling clamp 100ohm according to IEC 61000-4-4 including 1m coax cable with BNC connectors.
    VERI-CP-EFT Transducer plate for capacitive coupling clamp calibration. Connector HV BNC with 15cm strap to bond to the reference ground plane.
    CN-BALUN Balanced/unbalanced transmission line transformer for EFT and 1MHz damped sine according to ANSI/IEEE C.37.90. Including coaxial cable with HV-BNC plugs (3x 0.5m), test tip + HV-BNC adapter (1 red, 1 black) and HV-BNC connector (2x).
    VERI50EFT 50ohm termination with high voltage BNC connector and integrated divider for EFT calibration / verification in accordance with IEC 61000-4-4 Ed2.
    VERI1K EFT 1kOhm termination with high voltage BNC connector and integrated divider for EFT calibration / verification in accordance with IEC 61000-4-4 Ed2.

    Номер в
    госреестре
    Наименование СИ Обозначение типа СИ Изготовитель Срок свидетельства
    или заводской номер
    Не подлежит сертификации

    Запросить цену можно по телефону или заполнив эту несложную форму.

    ФИО:

    Компания:

    Контактные данные: