  • EMC Partner TRA3000 с модулем F/F5

    Дополнительная информация


    Test System Features

    Transient 3000 CE Test System has many unique and outstanding features:
    - Modular design, user configurable
    - Environmentally friendly
    - Humidity, pressure and temperature sensor measure lab environment
    - Automatic frequency detection for mains synchronisation (50 to 400Hz)
    - Internal web server
    - Ethernet Port for control, communication and report generation
    - USB Port: Secure transfer of files, test reports and service data
    - Common Mode Disturbances DC to 150kHz 30V continuous, 300V short duration
    - ESD 16kV air / 10kV contact discharge
    - ESD 16kV continuous firing mode.
    - Choice of EFT/Burst modules 4kV or 5kV
    - CWG surge up to 4kV/2kA
    - AC Magnetic Field up to 1000A/m (with external antenna)
    - Impulse Magnetic Field 1200A/m
    - AC Interrupt 260V/16A
    - AC DIP and VARIATION with internal, external variac or PS3 power supply
    - DC Interrupt 110V/16A
    - RS485 Port for control of external accessories
    - Control of up to two external PS3 power supplies

    User Benefits

    The technical excellence and many unique features translate directly into benefits for the user:
    - Optimized investment. Feature expansion by on-site upgrades
    - No down time: Modules can be removed for calibration
    - Unparalleled reliability and system up-time
    - Display information in any operating system with any web browser
    - Customized test report, logo import, graphics, time and date
    - Test report includes laboratory environmental conditions
    - No proprietary software needed: HTML Report viewable with all browsers
    - Active energy control system: Low power consumption, less noise, less heat
    - Backwards compatibility: Existing accessories can be used with all models
    - 400Hz CDN use for military and avionics testing
    - Optimized for CE transient testing: Fulfills IEC basic standard requirements
    - Clear menu overview: Structure automatically adjusts to hardware configuration
    - Expansion to 3-phase test system up to 100A
    - Operating history stored in generator for service
    - Modern communication interfaces connect TRA3000 to the world
    - Save operator time with the automated test routines and test report facility

    TRA3000 BASE
    Supply voltage range 80 to 260V / 50Hz & 60Hz
    Standby current 50VA
    Internal CDN voltage rating 280Vac & 110Vdc
    Internal CDN current rating 16Aac & 16Adc
    Internal CDN frequency range 50 to 400Hz
    Power frequency synchronisation 16Hz up to 400Hz
    Coupling path selection EFT L, N, PE, L+N, L+PE, N+PE, L+N+ PE
    Coupling path selection surge L - N, L - PE, N - PE
    Communication Interface Ethernet
    Accessory control interface RS485
    Memory locations unlimited
    Atmospheric measurement Temperature & Humidity
    PS3 control DC, 16.7Hz, 50Hz, 60Hz, 400Hz
    EUT Power monitor 10V =400Vac
    Surge voltage monitor 10V =4kV
    Surge current monitor 10V =2kA
    Trigger BNC maximum 12V
    Trigger mode Auto, manual
    Synchro source Power, external
    Power synchro on/off 0 - 360°
    Power switching before / after test 0 up to 60min.
    EXF-TRA3000 F FAST TRANSIENT 4kV
    Voltage range 0.25 up to 4.4kV
    Source impedance 50ohm
    Pulse front time at 50ohm 5ns
    Pulse duration at 50ohm 50ns
    Spike repetition frequency up to 1MHz
    Programmable parameter ramps voltage, spike frequency, burst duration, synchronisation
    Spike distribution IEC burst pattern and random
    Burst duration 0.01 up to 30ms
    Burst repetition 1 up to 1000ms
    Polarity Positive and Negative
    EXF-TRA3000 F5 FAST TRANSIENT 5kV
    Voltage range 0.25 up to 5.1kV
    Source impedance 50ohm
    Pulse front time at 50ohm 5ns
    Pulse duration at 50ohm 50ns
    Spike repetition frequency up to 1MHz
    Programmable parameter ramps voltage, spike frequency, burst duration, synchronisation
    Spike distribution IEC burst pattern and random
    Burst duration 0.01 up to 30ms
    Burst repetition 1 up to 1000ms
    Polarity Positive and Negative
    S
    T
    A
    N
    D
    A
    R
    D
    S
    T
    R
    A
    3
    0
    0
    0
     
    B
    A
    S
    E
    E
    F
    T
    /
    B
    u
    r
    s
    t
    S
    U
    R
    G
    E
    D
    I
    P
    S
     
    (
    I
    N
    T
    E
    R
    R
    U

    P
    T
    )
    V
    A
    R
    I
    A
    C
    C
    O
    M
    M
    O
    N
     
    M

    O
    D
    E
     
    (
    I
    N
    T
    )
    V
    A
    R
    -
    E
    X
    T

    1
    0
    0
    0
    M
    F
    1
    0
    0
    0

    -
    1
     
    C
    N
    1
    6
     

    (
    T
    )

    C
    N
    -
    E
    F
    T

    1
    0
    0
    0

    P
    S
    3
    E
    X
    T
    -
    T
    R

    A
    3
    0
    0
     E
    C
    O
    M
    M
    O
    N
     
    M
    O
    D
    E
     
    (
    E
    X
    T
    )
    IEC61000-4-2
    IEC61000-4-4
    IEC61000-4-5
    IEC61000-4-8 1
    IEC61000-4-9
    IEC61000-4-11 2 2 3
    IEC61000-4-16
    IEC61000-4-29 4
    ● = necessary  □ = options
    1. PS3 can be used for magnetic field testing including 16.7Hz
    2. Internal and external variac >500A inrush current
    3. PS3 ca. 100A inrush current
    4. Requires 2 x PS3

    IEFT / Burst
    CN-EFT1000 Capacitive coupling clamp 100ohm according to IEC 61000-4-4 including 1m coax cable with BNC connectors.
    VERI-CP-EFT Transducer plate for capacitive coupling clamp calibration. Connector HV BNC with 15cm strap to bond to the reference ground plane.  
    CN-BALUN Balanced/unbalanced transmission line transformer for EFT and 1MHz damped sine according to ANSI/IEEE C.37.90. Including coaxial cable with HV-BNC plugs (3x 0.5m), test tip + HV-BNC adapter (1 red, 1 black) and HV-BNC connector (2x).
    VERI50EFT 50ohm termination with high voltage BNC connector and integrated divider for EFT calibration / verification in accordance with IEC 61000-4-4 Ed2.
    VERI1KEFT 1kOhm termination with high voltage BNC connector and integrated divider for EFT calibration / verification in accordance with IEC 61000-4-4 Ed2.

    Номер в
    госреестре
    Наименование СИ Обозначение типа СИ Изготовитель Срок свидетельства
    или заводской номер
    Не подлежит сертификации

    Запросить цену можно по телефону или заполнив эту несложную форму.

    ФИО:

    Компания:

    Контактные данные: